Search results for "reduced graphene oxide"
showing 10 items of 13 documents
Novel diamond X-ray detectors with patterned reduced graphene oxide contacts
2015
A novel kind of detector based on polycrystalline grade diamond substrate and Reduced Graphene Oxide (RGO) contacts is presented. This detector combines some of the good qualities of diamond (i.e. radiation hardness and almost unique combination of electric, thermal and optical properties) with low- Z contacts. This characteristic together with the possibility of patterning the electrodes with standard lithographic techniques, make this detector particularly suitable for X-ray beam monitors where the intensity and the position of the photon beam needs to be measured with minimal effect on the beam itself (i.e. in-line and highly transmissive measurement). The steps needed to realize our nov…
Ascorbic Acid determination using linear sweep voltammetry on flexible electrode modified with gold nanoparticles and reduced graphene oxide
2020
Indium tin oxide (ITO) coated on flexible polyethylene terephthalate (PET) substrate electrode was modified with reduced graphene oxide and gold nanoparticles by simple co-electrodeposition performed at -0.8 V vs SCE for 200 s. All samples were characterized by electron scan microscopy. The as prepared electrode was used as electrochemical sensor to selective detection of ascorbic acid using linear sweep voltammetry. Excellent results were obtained in a linear range from 20 to 150 µM of ascorbic acid with a limit of detection of about 3.1 µM (S/N=3.3). The sensors have a reproducibility of about 5.5% and also show high selectivity towards different interferents such as chlorine, calcium, ma…
Investigation of Acetone Vapour Sensing Properties of a Ternary Composite of Doped Polyaniline, Reduced Graphene Oxide and Chitosan Using Surface Pla…
2020
This work reports the use of a ternary composite that integrates p-Toluene sulfonic acid doped polyaniline (PANI), chitosan, and reduced graphene oxide (RGO) as the active sensing layer of a surface plasmon resonance (SPR) sensor. The SPR sensor is intended for application in the non-invasive monitoring and screening of diabetes through the detection of low concentrations of acetone vapour of less than or equal to 5 ppm, which falls within the range of breath acetone concentration in diabetic patients. The ternary composite film was spin-coated on a 50-nm-thick gold layer at 6000 rpm for 30 s. The structure, morphology and chemical composition of the ternary composite samples were character…
PANI-Based Wearable Electrochemical Sensor for pH Sweat Monitoring
2021
Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic…
C3N4/reduced graphene oxide photocatalysts loaded with Ag or Ag/Pt for H2 evolution from aqueous solution of triethanolamine
2023
Composites of C3N4/reduced graphene oxide have been used as photocatalysts for triethanolamine photo- reforming with H2 generation in aqueous solution. The rate of H2 production over the Ag loaded best per- forming photocatalyst reached 525 μmol⋅h
FABBRICAZIONE DI SENSORI ELETTROCHIMICI NANOSTRUTTURATI PER APPLICAZIONI NELL’INDUSTRIA ALIMENTARE E BIOMEDICHE
2023
DOPAMINE ELECTROCHEMICAL SENSOR BASED ON REDUCED GRAPHENE OXIDE AND METAL NANOPARTICLES
2019
Dopamine (DA) is one of the most important neurotransmitters released from the brain, and is involved in many different biological processes. This neurotransmitter influences the processes that involve memory, sleep, mood, learning, and so on. Besides, in the last years, dopamine concentration in human body fluids has been related to some neurodegenerative pathologies, such as Parkinson and Alzheimer’s diseases [1]. It is well known that these pathologies are due to the formation of amyloids plaques that block part of the brain. Many literature data reports that DAergic neurons (areas of midbrain where DA is synthesized) shows a different activity when amyloid plaques are present with a con…
Phosphate ions detection by using an electrochemical sensor based on laser-scribed graphene oxide on paper
2023
In this work, electrodes based on laser-scribed reduced graphene oxide were fabricated using filter paper as the substrate. To fabricate the electrodes, a water suspension of graphene oxide was filtered to produce a continuous and uniform film of graphene oxide on the filter paper surface. Subsequently, a CO2 laser was used to "write" the working, counter and reference eelctroes by reducing graphene oxide in specific areas to define complete sensors. Referecnce electrodes were then coated with a commercial Ag/AgCl conductive paste to produce a quasi Ag/AgCl reference. As fabricated devices were employed as electrochemical sensors for detection of phosphate ions in water by employing the mol…
Nanostructured Lead Electrodes with Reduced Graphene Oxide for High-Performance Lead–Acid Batteries
2022
Nanostructured Pb electrodes consisting of nanowire arrays were obtained by electrodeposition, to be used as negative electrodes for lead–acid batteries. Reduced graphene oxide was added to improve their performances. This was achieved via the electrochemical reduction of graphene oxide directly on the surface of nanowire arrays. The electrodes with and without reduced graphene oxide were tested in a 5 M sulfuric acid solution using a commercial pasted positive plate and an absorbed glass mat separator in a zero-gap configuration. The electrodes were tested in deep cycling conditions with a very low cut-off potential. Charge–discharge tests were performed at 5C. The electrode wi…
FLEXIBLE ELECTRODE BASED ON GOLD NANOPARTICLES AND REDUCED GRAPHENE OXIDE FOR URIC ACID DETECTION USING LINEAR SWEEP VOLTAMMETRY
2021
In this work, an electrochemical sensor for uric acid determination is shown with a preliminary study for its validation in real samples (milk and urine). Uric acid can be electrochemically oxidized in aqueous solutions and thus it is possible to obtain electrochemical sensors for this chemical by means of this electrooxidation reaction. Indium tin oxide coated on flexible polyethylene terephthalate substrate, modified with reduced graphene oxide and gold nanoparticles by co-electrodeposition, was used. Electrodeposition was performed at -0.8V vs SCE for 200 s. All samples were characterized by electron scan microscopy and electron diffraction spectroscopy. A careful investigation on the ef…